Architectural Specifications
3.1 Access 700 PWI1 ED5000N Exit Devices
Intelligent WiFi Access Control Rim & Mortise Exit Devices
A. WiFi Access Control Rim & Mortise Exit Devices to be ED5000N Series as manufactured by
Corbin Russwin of Berlin, CT.
B. BHMA certified panic and exit device hardware conforming to ANSI 156.3, Grade 1 standard
and ANSI A117.1 accessibility guidelines. Electronic motorized locking control of lever handle
(solenoids not acceptable) contained completely within the body of the outside trim control.
U.L. listed and labeled for either panic or “Fire Exit Hardware” for use on up to 3 hour fire rated
openings.
1. Mortise Exit Devices shall utilize a 3/4" anti-friction deadlocking latch and 1" case-
hardened steel deadbolt with a 2-3/4” Backset.
C. WiFi access control locking devices interface using field replaceable IEEE 802.11 b/g/n, 2.4
GHz wireless radio connection to an Ethernet Local Area Network (LAN) facilitating centralized
control via a Software Development Kit (SDK). Locks will continue to operate independent of
Ethernet (LAN) wireless connection slowdown or failure.
1. Provide access control products with non-volatile memory.
D. Supports WEP, WPA, WPA2 and 802.1x wireless encryption (IEEE 802.11 b/g/n, 2.4 GHz). AES
128 encrypted communication between IP Enabled lock and electronic access control system
platform via SDK. Programmable time zone periods, blocked holidays, automatic unlock with
or without first entry, minimum of 2,400 user codes and the ability to audit the last 10,000
transactions (event type, date, time, user ID and name). Distributed intelligence allows stand
alone functional operation of lock in absence of network communication or slowdown allowing
for system operational redundancy.
E. Integrated reader supports High Coercivity (HiCo) magnetic swipe credentials, HID
®
125 kHz
proximity credentials or ISO 14443 A/B and ISO 15693 13.56 MHz contactless credentials:
HID
®
iCLASS / iCLASS SE (full authentication, all formats), MIFARE Classic and DESFire EV1 (full
authentication, all formats); NFC (Near Field Communications) and HID
®
SIO-Enabled™.
1. Valid/ Invalid credential presentation viewable by means of LED indicators on outside
escutcheon.
2. Dual factor keypad authentication function optional.
F. Environmental Conditions: Conformally coated weather resistant electronic controller shall meet
the following minimum requirements:
1. Operating temperature: -13°F (-25°C) to 151°F (66°C)
2. Operating humidity: < 85% non-condensing
3. Weatherized design suitable to withstand harsh environments with a certified rating of IP55
G. Configuration: Programming of time zone periods, blocked holidays, automatic unlock with or
without first entry, and listing 10,000 event transaction history consisting of event type, date,
time, user ID and name is required.
1. Provide network and lock configuration CD tool kit for initial lock set-up and programming
via USB connection.
H. Monitoring: Software accessible monitoring (via SDK) of inside push rail (Request-to-Exit),
integral door position switch (DPS) integral to the lock (door open/closed status), forced door,
unknown card, door held open, battery and tamper.
1. Standard privacy function initiated from push button on inside escutcheon and cancelled
upon activation of valid Request-To-Exit (REX) or user defined credentials.
a. Activation of privacy function is indicated by LED notification on inside escutcheon.
b. Redundant actuation of privacy button does not deactivate privacy mode.
I. Emergency override access capability by mechanical key cylinder retraction of lock latch bolt
without electronic activation necessary.
1. Provide keyed cylinder dogging feature for non-rated panic devices and keyed removable
mullions as specified.
J. Inside push bar retracts latch bolt for free egress.
K. Power Source: Powered by 6 AA alkaline batteries with LED indication of locked, programming
mode and low capacity warning status conditions.
1. Optional hard power by means of 12-24 VDC power supply.
L. Cylinders: Reference 2.04 Keying for keying requirements